1 | (export (version D)
|
---|
2 | (design
|
---|
3 | (source "C:\\Users\\pulkomandy\\Documents\\DEV\\avrstuff\\CPC stuff\\ch376\\ramcard.sch")
|
---|
4 | (date "17/10/2015 13:26:52")
|
---|
5 | (tool "Eeschema 4.0.0-rc1-stable")
|
---|
6 | (sheet (number 1) (name /) (tstamps /)
|
---|
7 | (title_block
|
---|
8 | (title "CH376 CPC USB interface")
|
---|
9 | (company PulkoTronics)
|
---|
10 | (rev)
|
---|
11 | (date 2015-10-14)
|
---|
12 | (source ramcard.sch)
|
---|
13 | (comment (number 1) (value ""))
|
---|
14 | (comment (number 2) (value ""))
|
---|
15 | (comment (number 3) (value ""))
|
---|
16 | (comment (number 4) (value "")))))
|
---|
17 | (components
|
---|
18 | (comp (ref IC1)
|
---|
19 | (value 74LS20)
|
---|
20 | (footprint Housings_SOIC:SOIC-14_3.9x8.7mm_Pitch1.27mm)
|
---|
21 | (libsource (lib 74xx) (part 74LS20))
|
---|
22 | (sheetpath (names /) (tstamps /))
|
---|
23 | (tstamp 5058DC2F))
|
---|
24 | (comp (ref IC2)
|
---|
25 | (value 74LS02)
|
---|
26 | (footprint Housings_DIP:DIP-14_W7.62mm)
|
---|
27 | (libsource (lib 74xx) (part 74LS02))
|
---|
28 | (sheetpath (names /) (tstamps /))
|
---|
29 | (tstamp 5058DBC7))
|
---|
30 | (comp (ref C4)
|
---|
31 | (value 0.1u)
|
---|
32 | (footprint Capacitors_ThroughHole:C_Disc_D3_P2.5)
|
---|
33 | (libsource (lib device) (part C))
|
---|
34 | (sheetpath (names /) (tstamps /))
|
---|
35 | (tstamp 4CA87152))
|
---|
36 | (comp (ref C3)
|
---|
37 | (value C)
|
---|
38 | (footprint Capacitors_ThroughHole:C_Disc_D3_P2.5)
|
---|
39 | (libsource (lib device) (part C))
|
---|
40 | (sheetpath (names /) (tstamps /))
|
---|
41 | (tstamp 4CA87151))
|
---|
42 | (comp (ref P1)
|
---|
43 | (value CONN_25X2)
|
---|
44 | (footprint Pin_Headers:Pin_Header_Straight_2x25)
|
---|
45 | (libsource (lib ramcard-cache) (part CONN_25X2))
|
---|
46 | (sheetpath (names /) (tstamps /))
|
---|
47 | (tstamp 4CA8712F))
|
---|
48 | (comp (ref C2)
|
---|
49 | (value C)
|
---|
50 | (footprint Capacitors_ThroughHole:C_Disc_D3_P2.5)
|
---|
51 | (libsource (lib device) (part C))
|
---|
52 | (sheetpath (names /) (tstamps /))
|
---|
53 | (tstamp 4CA870EF))
|
---|
54 | (comp (ref C1)
|
---|
55 | (value C)
|
---|
56 | (footprint Capacitors_ThroughHole:C_Disc_D3_P2.5)
|
---|
57 | (libsource (lib device) (part C))
|
---|
58 | (sheetpath (names /) (tstamps /))
|
---|
59 | (tstamp 561ECD91))
|
---|
60 | (comp (ref IC3)
|
---|
61 | (value 74LS138)
|
---|
62 | (footprint Housings_DIP:DIP-16_W7.62mm)
|
---|
63 | (libsource (lib 74xx) (part 74LS138))
|
---|
64 | (sheetpath (names /) (tstamps /))
|
---|
65 | (tstamp 561ED197))
|
---|
66 | (comp (ref IC4)
|
---|
67 | (value CH376)
|
---|
68 | (footprint SMD_Packages:SOJ-28-W)
|
---|
69 | (libsource (lib ch376) (part CH376))
|
---|
70 | (sheetpath (names /) (tstamps /))
|
---|
71 | (tstamp 56214228))
|
---|
72 | (comp (ref P2)
|
---|
73 | (value USB_A)
|
---|
74 | (footprint Connect:USB_A)
|
---|
75 | (libsource (lib conn) (part USB_A))
|
---|
76 | (sheetpath (names /) (tstamps /))
|
---|
77 | (tstamp 56215113))
|
---|
78 | (comp (ref Y1)
|
---|
79 | (value Crystal_Small)
|
---|
80 | (footprint Crystals:Crystal_HC49-U_Vertical)
|
---|
81 | (libsource (lib device) (part Crystal_Small))
|
---|
82 | (sheetpath (names /) (tstamps /))
|
---|
83 | (tstamp 56215654))
|
---|
84 | (comp (ref R1)
|
---|
85 | (value 2R)
|
---|
86 | (footprint Resistors_Universal:Resistor_SMD+THTuniversal_0805to1206_RM10_HandSoldering)
|
---|
87 | (libsource (lib device) (part R))
|
---|
88 | (sheetpath (names /) (tstamps /))
|
---|
89 | (tstamp 56215821))
|
---|
90 | (comp (ref C5)
|
---|
91 | (value 100u)
|
---|
92 | (footprint Capacitors_ThroughHole:C_Radial_D5_L6_P2.5)
|
---|
93 | (libsource (lib device) (part CP))
|
---|
94 | (sheetpath (names /) (tstamps /))
|
---|
95 | (tstamp 56215B06))
|
---|
96 | (comp (ref C6)
|
---|
97 | (value 0.01u)
|
---|
98 | (footprint Capacitors_SMD:C_1206_HandSoldering)
|
---|
99 | (libsource (lib device) (part C))
|
---|
100 | (sheetpath (names /) (tstamps /))
|
---|
101 | (tstamp 562163D5))
|
---|
102 | (comp (ref U1)
|
---|
103 | (value LD1117S33CTR)
|
---|
104 | (footprint TO_SOT_Packages_SMD:SOT-223)
|
---|
105 | (libsource (lib regul) (part LD1117S33CTR))
|
---|
106 | (sheetpath (names /) (tstamps /))
|
---|
107 | (tstamp 562212C4))
|
---|
108 | (comp (ref C7)
|
---|
109 | (value 10u)
|
---|
110 | (footprint Capacitors_ThroughHole:C_Radial_D5_L6_P2.5)
|
---|
111 | (libsource (lib device) (part CP))
|
---|
112 | (sheetpath (names /) (tstamps /))
|
---|
113 | (tstamp 56221A22))
|
---|
114 | (comp (ref U2)
|
---|
115 | (value CONN_SD)
|
---|
116 | (footprint opendous:Memory_Card_microSD_DM3CS-SF)
|
---|
117 | (libsource (lib opendous) (part CONN_SD))
|
---|
118 | (sheetpath (names /) (tstamps /))
|
---|
119 | (tstamp 56222F70)))
|
---|
120 | (libparts
|
---|
121 | (libpart (lib conn) (part USB_A)
|
---|
122 | (description "A connector")
|
---|
123 | (footprints
|
---|
124 | (fp USB*))
|
---|
125 | (fields
|
---|
126 | (field (name Reference) P)
|
---|
127 | (field (name Value) USB_A))
|
---|
128 | (pins
|
---|
129 | (pin (num 1) (name VCC) (type power_in))
|
---|
130 | (pin (num 2) (name D-) (type passive))
|
---|
131 | (pin (num 3) (name D+) (type passive))
|
---|
132 | (pin (num 4) (name GND) (type power_in))
|
---|
133 | (pin (num 5) (name shield) (type passive))))
|
---|
134 | (libpart (lib 74xx) (part 74LS02)
|
---|
135 | (aliases
|
---|
136 | (alias 74HC02)
|
---|
137 | (alias 74HCT02)
|
---|
138 | (alias 7402)
|
---|
139 | (alias 74LS28))
|
---|
140 | (description "Quad Nor2")
|
---|
141 | (footprints
|
---|
142 | (fp SO14*)
|
---|
143 | (fp 14DIP*))
|
---|
144 | (fields
|
---|
145 | (field (name Reference) U)
|
---|
146 | (field (name Value) 74LS02))
|
---|
147 | (pins
|
---|
148 | (pin (num 1) (name ~) (type output))
|
---|
149 | (pin (num 2) (name ~) (type input))
|
---|
150 | (pin (num 3) (name ~) (type input))
|
---|
151 | (pin (num 4) (name ~) (type output))
|
---|
152 | (pin (num 5) (name ~) (type input))
|
---|
153 | (pin (num 6) (name ~) (type input))
|
---|
154 | (pin (num 7) (name GND) (type power_in))
|
---|
155 | (pin (num 8) (name ~) (type input))
|
---|
156 | (pin (num 9) (name ~) (type input))
|
---|
157 | (pin (num 10) (name ~) (type output))
|
---|
158 | (pin (num 11) (name ~) (type input))
|
---|
159 | (pin (num 12) (name ~) (type input))
|
---|
160 | (pin (num 13) (name ~) (type output))
|
---|
161 | (pin (num 14) (name VCC) (type power_in))))
|
---|
162 | (libpart (lib 74xx) (part 74LS138)
|
---|
163 | (description "Decoder 3 to 8 (active low outputs)")
|
---|
164 | (fields
|
---|
165 | (field (name Reference) U)
|
---|
166 | (field (name Value) 74LS138))
|
---|
167 | (pins
|
---|
168 | (pin (num 1) (name A0) (type input))
|
---|
169 | (pin (num 2) (name A1) (type input))
|
---|
170 | (pin (num 3) (name A2) (type input))
|
---|
171 | (pin (num 4) (name E1) (type input))
|
---|
172 | (pin (num 5) (name E2) (type input))
|
---|
173 | (pin (num 6) (name E3) (type input))
|
---|
174 | (pin (num 7) (name O7) (type output))
|
---|
175 | (pin (num 8) (name GND) (type power_in))
|
---|
176 | (pin (num 9) (name O6) (type output))
|
---|
177 | (pin (num 10) (name O5) (type output))
|
---|
178 | (pin (num 11) (name O4) (type output))
|
---|
179 | (pin (num 12) (name O3) (type output))
|
---|
180 | (pin (num 13) (name O2) (type output))
|
---|
181 | (pin (num 14) (name O1) (type output))
|
---|
182 | (pin (num 15) (name O0) (type output))
|
---|
183 | (pin (num 16) (name VCC) (type power_in))))
|
---|
184 | (libpart (lib 74xx) (part 74LS20)
|
---|
185 | (aliases
|
---|
186 | (alias 74LS22)
|
---|
187 | (alias 74LS40))
|
---|
188 | (description "Dual Nand 4 inputs")
|
---|
189 | (fields
|
---|
190 | (field (name Reference) U)
|
---|
191 | (field (name Value) 74LS20))
|
---|
192 | (pins
|
---|
193 | (pin (num 1) (name ~) (type input))
|
---|
194 | (pin (num 2) (name ~) (type input))
|
---|
195 | (pin (num 4) (name ~) (type input))
|
---|
196 | (pin (num 5) (name ~) (type input))
|
---|
197 | (pin (num 6) (name ~) (type output))
|
---|
198 | (pin (num 7) (name GND) (type power_in))
|
---|
199 | (pin (num 8) (name ~) (type output))
|
---|
200 | (pin (num 9) (name ~) (type input))
|
---|
201 | (pin (num 10) (name ~) (type input))
|
---|
202 | (pin (num 12) (name ~) (type input))
|
---|
203 | (pin (num 13) (name ~) (type input))
|
---|
204 | (pin (num 14) (name VCC) (type power_in))))
|
---|
205 | (libpart (lib regul) (part LD1117S33TR)
|
---|
206 | (aliases
|
---|
207 | (alias LD1117S33CTR)
|
---|
208 | (alias LD1117S12TR)
|
---|
209 | (alias LD1117S12CTR)
|
---|
210 | (alias LD1117S18TR)
|
---|
211 | (alias LD1117S18CTR)
|
---|
212 | (alias LD1117S25TR)
|
---|
213 | (alias LD1117S25CTR)
|
---|
214 | (alias LD1117S50TR)
|
---|
215 | (alias LD1117S50CTR))
|
---|
216 | (description "800mA Fixed Low Drop Positive Voltage Regulator, Fixed Output 3.3V, SOT223")
|
---|
217 | (docs http://www.st.com/st-web-ui/static/active/en/resource/technical/document/datasheet/CD00000544.pdf)
|
---|
218 | (footprints
|
---|
219 | (fp SOT223))
|
---|
220 | (fields
|
---|
221 | (field (name Reference) U)
|
---|
222 | (field (name Value) LD1117S33TR)
|
---|
223 | (field (name Footprint) SOT-223))
|
---|
224 | (pins
|
---|
225 | (pin (num 1) (name GND) (type power_in))
|
---|
226 | (pin (num 2) (name VO) (type power_out))
|
---|
227 | (pin (num 3) (name VI) (type power_in))))
|
---|
228 | (libpart (lib ch376) (part CH376)
|
---|
229 | (fields
|
---|
230 | (field (name Reference) IC)
|
---|
231 | (field (name Value) CH376))
|
---|
232 | (pins
|
---|
233 | (pin (num 1) (name /INT) (type output))
|
---|
234 | (pin (num 2) (name RSTI) (type input))
|
---|
235 | (pin (num 3) (name /WR) (type input))
|
---|
236 | (pin (num 4) (name /RD) (type input))
|
---|
237 | (pin (num 5) (name TXD) (type output))
|
---|
238 | (pin (num 6) (name RXD) (type input))
|
---|
239 | (pin (num 7) (name SD_DI) (type input))
|
---|
240 | (pin (num 8) (name A0) (type input))
|
---|
241 | (pin (num 9) (name V3) (type power_in))
|
---|
242 | (pin (num 10) (name UD+) (type BiDi))
|
---|
243 | (pin (num 11) (name UD-) (type BiDi))
|
---|
244 | (pin (num 12) (name GND) (type power_in))
|
---|
245 | (pin (num 13) (name XI) (type input))
|
---|
246 | (pin (num 14) (name XO) (type output))
|
---|
247 | (pin (num 15) (name D0) (type BiDi))
|
---|
248 | (pin (num 16) (name D1) (type BiDi))
|
---|
249 | (pin (num 17) (name D2) (type BiDi))
|
---|
250 | (pin (num 18) (name D3) (type BiDi))
|
---|
251 | (pin (num 19) (name D4) (type BiDi))
|
---|
252 | (pin (num 20) (name D5) (type BiDi))
|
---|
253 | (pin (num 21) (name D6) (type BiDi))
|
---|
254 | (pin (num 22) (name D7) (type BiDi))
|
---|
255 | (pin (num 23) (name SD_CS) (type output))
|
---|
256 | (pin (num 24) (name /ACT) (type output))
|
---|
257 | (pin (num 25) (name SD_DO) (type output))
|
---|
258 | (pin (num 26) (name SD_CK) (type output))
|
---|
259 | (pin (num 27) (name /PCS) (type input))
|
---|
260 | (pin (num 28) (name VCC) (type power_in))))
|
---|
261 | (libpart (lib device) (part R)
|
---|
262 | (description Resistor)
|
---|
263 | (footprints
|
---|
264 | (fp R_*)
|
---|
265 | (fp Resistor_*))
|
---|
266 | (fields
|
---|
267 | (field (name Reference) R)
|
---|
268 | (field (name Value) R))
|
---|
269 | (pins
|
---|
270 | (pin (num 1) (name ~) (type passive))
|
---|
271 | (pin (num 2) (name ~) (type passive))))
|
---|
272 | (libpart (lib device) (part Crystal_Small)
|
---|
273 | (description "Two pin crystal")
|
---|
274 | (footprints
|
---|
275 | (fp Crystal_))
|
---|
276 | (fields
|
---|
277 | (field (name Reference) Y)
|
---|
278 | (field (name Value) Crystal_Small))
|
---|
279 | (pins
|
---|
280 | (pin (num 1) (name 1) (type passive))
|
---|
281 | (pin (num 2) (name 2) (type passive))))
|
---|
282 | (libpart (lib device) (part CP)
|
---|
283 | (description "Polarised capacitor")
|
---|
284 | (footprints
|
---|
285 | (fp CP*)
|
---|
286 | (fp Elko*)
|
---|
287 | (fp TantalC*)
|
---|
288 | (fp C*elec)
|
---|
289 | (fp c_elec*)
|
---|
290 | (fp SMD*_Pol))
|
---|
291 | (fields
|
---|
292 | (field (name Reference) C)
|
---|
293 | (field (name Value) CP))
|
---|
294 | (pins
|
---|
295 | (pin (num 1) (name ~) (type passive))
|
---|
296 | (pin (num 2) (name ~) (type passive))))
|
---|
297 | (libpart (lib device) (part C)
|
---|
298 | (description "Unpolarized capacitor")
|
---|
299 | (footprints
|
---|
300 | (fp C?)
|
---|
301 | (fp C_????_*)
|
---|
302 | (fp C_????)
|
---|
303 | (fp SMD*_c)
|
---|
304 | (fp Capacitor*))
|
---|
305 | (fields
|
---|
306 | (field (name Reference) C)
|
---|
307 | (field (name Value) C))
|
---|
308 | (pins
|
---|
309 | (pin (num 1) (name ~) (type passive))
|
---|
310 | (pin (num 2) (name ~) (type passive))))
|
---|
311 | (libpart (lib opendous) (part CONN_SD)
|
---|
312 | (fields
|
---|
313 | (field (name Reference) U)
|
---|
314 | (field (name Value) CONN_SD))
|
---|
315 | (pins
|
---|
316 | (pin (num 1) (name DAT3) (type BiDi))
|
---|
317 | (pin (num 2) (name CMD) (type input))
|
---|
318 | (pin (num 3) (name GND) (type power_in))
|
---|
319 | (pin (num 4) (name VCC) (type power_in))
|
---|
320 | (pin (num 5) (name CLK) (type input))
|
---|
321 | (pin (num 6) (name GND) (type power_in))
|
---|
322 | (pin (num 7) (name DAT0) (type BiDi))
|
---|
323 | (pin (num 8) (name DAT1) (type BiDi))
|
---|
324 | (pin (num 9) (name DAT2) (type BiDi))
|
---|
325 | (pin (num 14) (name WP) (type input))
|
---|
326 | (pin (num 15) (name CD) (type input))
|
---|
327 | (pin (num 16) (name GND) (type power_in))
|
---|
328 | (pin (num 17) (name GND) (type power_in))))
|
---|
329 | (libpart (lib ramcard-cache) (part CONN_25X2)
|
---|
330 | (fields
|
---|
331 | (field (name Reference) P)
|
---|
332 | (field (name Value) CONN_25X2))
|
---|
333 | (pins
|
---|
334 | (pin (num 1) (name P1) (type passive))
|
---|
335 | (pin (num 2) (name P2) (type passive))
|
---|
336 | (pin (num 3) (name P3) (type passive))
|
---|
337 | (pin (num 4) (name P4) (type passive))
|
---|
338 | (pin (num 5) (name P5) (type passive))
|
---|
339 | (pin (num 6) (name P6) (type passive))
|
---|
340 | (pin (num 7) (name P7) (type passive))
|
---|
341 | (pin (num 8) (name P8) (type passive))
|
---|
342 | (pin (num 9) (name P9) (type passive))
|
---|
343 | (pin (num 10) (name P10) (type passive))
|
---|
344 | (pin (num 11) (name P11) (type passive))
|
---|
345 | (pin (num 12) (name P12) (type passive))
|
---|
346 | (pin (num 13) (name P13) (type passive))
|
---|
347 | (pin (num 14) (name P14) (type passive))
|
---|
348 | (pin (num 15) (name P15) (type passive))
|
---|
349 | (pin (num 16) (name P16) (type passive))
|
---|
350 | (pin (num 17) (name P17) (type passive))
|
---|
351 | (pin (num 18) (name P18) (type passive))
|
---|
352 | (pin (num 19) (name P19) (type passive))
|
---|
353 | (pin (num 20) (name P20) (type passive))
|
---|
354 | (pin (num 21) (name P21) (type passive))
|
---|
355 | (pin (num 22) (name P22) (type passive))
|
---|
356 | (pin (num 23) (name P23) (type input))
|
---|
357 | (pin (num 24) (name P24) (type passive))
|
---|
358 | (pin (num 25) (name P25) (type input))
|
---|
359 | (pin (num 26) (name P26) (type passive))
|
---|
360 | (pin (num 27) (name P27) (type passive))
|
---|
361 | (pin (num 28) (name P28) (type passive))
|
---|
362 | (pin (num 29) (name P29) (type passive))
|
---|
363 | (pin (num 30) (name P30) (type passive))
|
---|
364 | (pin (num 31) (name P31) (type passive))
|
---|
365 | (pin (num 32) (name P32) (type passive))
|
---|
366 | (pin (num 33) (name P33) (type passive))
|
---|
367 | (pin (num 34) (name P34) (type passive))
|
---|
368 | (pin (num 35) (name P35) (type passive))
|
---|
369 | (pin (num 36) (name P36) (type passive))
|
---|
370 | (pin (num 37) (name P37) (type passive))
|
---|
371 | (pin (num 38) (name P38) (type passive))
|
---|
372 | (pin (num 39) (name P39) (type passive))
|
---|
373 | (pin (num 40) (name P40) (type passive))
|
---|
374 | (pin (num 41) (name P41) (type passive))
|
---|
375 | (pin (num 42) (name P42) (type passive))
|
---|
376 | (pin (num 43) (name P43) (type passive))
|
---|
377 | (pin (num 44) (name P44) (type passive))
|
---|
378 | (pin (num 45) (name P45) (type passive))
|
---|
379 | (pin (num 46) (name P46) (type passive))
|
---|
380 | (pin (num 47) (name P47) (type passive))
|
---|
381 | (pin (num 48) (name P48) (type passive))
|
---|
382 | (pin (num 49) (name P49) (type passive))
|
---|
383 | (pin (num 50) (name P50) (type passive)))))
|
---|
384 | (libraries
|
---|
385 | (library (logical ramcard-cache)
|
---|
386 | (uri "C:\\Users\\pulkomandy\\Documents\\DEV\\avrstuff\\CPC stuff\\ch376\\ramcard-cache.lib"))
|
---|
387 | (library (logical device)
|
---|
388 | (uri "C:\\Program Files\\KiCad\\share\\kicad\\library\\device.lib"))
|
---|
389 | (library (logical conn)
|
---|
390 | (uri "C:\\Program Files\\KiCad\\share\\kicad\\library\\conn.lib"))
|
---|
391 | (library (logical 74xx)
|
---|
392 | (uri "C:\\Program Files\\KiCad\\share\\kicad\\library\\74xx.lib"))
|
---|
393 | (library (logical ch376)
|
---|
394 | (uri "C:\\Users\\pulkomandy\\Documents\\DEV\\avrstuff\\CPC stuff\\ch376\\ch376.lib"))
|
---|
395 | (library (logical regul)
|
---|
396 | (uri "C:\\Program Files\\KiCad\\share\\kicad\\library\\regul.lib"))
|
---|
397 | (library (logical opendous)
|
---|
398 | (uri "C:\\Users\\pulkomandy\\Documents\\DEV\\avrstuff\\CPC stuff\\kicadlibs\\Opendous_KiCad_Libraries\\library\\opendous.lib")))
|
---|
399 | (nets
|
---|
400 | (net (code 1) (name /A1)
|
---|
401 | (node (ref IC2) (pin 12))
|
---|
402 | (node (ref P1) (pin 17)))
|
---|
403 | (net (code 2) (name /A3)
|
---|
404 | (node (ref IC3) (pin 4))
|
---|
405 | (node (ref P1) (pin 15)))
|
---|
406 | (net (code 3) (name /A5)
|
---|
407 | (node (ref IC2) (pin 9))
|
---|
408 | (node (ref P1) (pin 13)))
|
---|
409 | (net (code 4) (name /A7)
|
---|
410 | (node (ref IC1) (pin 12))
|
---|
411 | (node (ref P1) (pin 11)))
|
---|
412 | (net (code 5) (name /A9)
|
---|
413 | (node (ref IC1) (pin 10))
|
---|
414 | (node (ref P1) (pin 9)))
|
---|
415 | (net (code 6) (name /A11)
|
---|
416 | (node (ref IC1) (pin 13))
|
---|
417 | (node (ref P1) (pin 7)))
|
---|
418 | (net (code 7) (name /A13)
|
---|
419 | (node (ref P1) (pin 5))
|
---|
420 | (node (ref IC1) (pin 2)))
|
---|
421 | (net (code 8) (name /A15)
|
---|
422 | (node (ref IC1) (pin 5))
|
---|
423 | (node (ref P1) (pin 3)))
|
---|
424 | (net (code 9) (name /A2)
|
---|
425 | (node (ref IC2) (pin 8))
|
---|
426 | (node (ref P1) (pin 16)))
|
---|
427 | (net (code 10) (name /A6)
|
---|
428 | (node (ref IC2) (pin 5))
|
---|
429 | (node (ref P1) (pin 12)))
|
---|
430 | (net (code 11) (name /A10)
|
---|
431 | (node (ref IC1) (pin 9))
|
---|
432 | (node (ref P1) (pin 8)))
|
---|
433 | (net (code 12) (name /A14)
|
---|
434 | (node (ref IC1) (pin 4))
|
---|
435 | (node (ref P1) (pin 4)))
|
---|
436 | (net (code 13) (name "Net-(P1-Pad42)")
|
---|
437 | (node (ref P1) (pin 42)))
|
---|
438 | (net (code 14) (name "Net-(P1-Pad43)")
|
---|
439 | (node (ref P1) (pin 43)))
|
---|
440 | (net (code 15) (name "Net-(P1-Pad50)")
|
---|
441 | (node (ref P1) (pin 50)))
|
---|
442 | (net (code 16) (name "Net-(P1-Pad46)")
|
---|
443 | (node (ref P1) (pin 46)))
|
---|
444 | (net (code 17) (name "Net-(P1-Pad29)")
|
---|
445 | (node (ref P1) (pin 29)))
|
---|
446 | (net (code 18) (name "Net-(P1-Pad37)")
|
---|
447 | (node (ref P1) (pin 37)))
|
---|
448 | (net (code 19) (name "Net-(P1-Pad41)")
|
---|
449 | (node (ref P1) (pin 41)))
|
---|
450 | (net (code 20) (name "Net-(P1-Pad47)")
|
---|
451 | (node (ref P1) (pin 47)))
|
---|
452 | (net (code 21) (name "Net-(IC2-Pad10)")
|
---|
453 | (node (ref IC3) (pin 2))
|
---|
454 | (node (ref IC2) (pin 10)))
|
---|
455 | (net (code 22) (name "Net-(IC2-Pad4)")
|
---|
456 | (node (ref IC2) (pin 4))
|
---|
457 | (node (ref IC3) (pin 1)))
|
---|
458 | (net (code 23) (name "Net-(IC1-Pad8)")
|
---|
459 | (node (ref IC1) (pin 8))
|
---|
460 | (node (ref IC2) (pin 3)))
|
---|
461 | (net (code 24) (name "Net-(IC1-Pad6)")
|
---|
462 | (node (ref IC1) (pin 6))
|
---|
463 | (node (ref IC2) (pin 2)))
|
---|
464 | (net (code 25) (name "Net-(P1-Pad45)")
|
---|
465 | (node (ref P1) (pin 45)))
|
---|
466 | (net (code 26) (name "Net-(P1-Pad28)")
|
---|
467 | (node (ref P1) (pin 28)))
|
---|
468 | (net (code 27) (name /FE80)
|
---|
469 | (node (ref IC4) (pin 27))
|
---|
470 | (node (ref IC3) (pin 7)))
|
---|
471 | (net (code 28) (name "Net-(IC4-Pad14)")
|
---|
472 | (node (ref IC4) (pin 14))
|
---|
473 | (node (ref Y1) (pin 2)))
|
---|
474 | (net (code 29) (name "Net-(IC4-Pad13)")
|
---|
475 | (node (ref Y1) (pin 1))
|
---|
476 | (node (ref IC4) (pin 13)))
|
---|
477 | (net (code 30) (name GND)
|
---|
478 | (node (ref U2) (pin 9))
|
---|
479 | (node (ref U2) (pin 6))
|
---|
480 | (node (ref U2) (pin 16))
|
---|
481 | (node (ref U2) (pin 17))
|
---|
482 | (node (ref IC3) (pin 8))
|
---|
483 | (node (ref P1) (pin 2))
|
---|
484 | (node (ref C3) (pin 2))
|
---|
485 | (node (ref C4) (pin 2))
|
---|
486 | (node (ref IC2) (pin 7))
|
---|
487 | (node (ref C5) (pin 2))
|
---|
488 | (node (ref U1) (pin 1))
|
---|
489 | (node (ref C7) (pin 2))
|
---|
490 | (node (ref U2) (pin 3))
|
---|
491 | (node (ref IC4) (pin 12))
|
---|
492 | (node (ref C6) (pin 2))
|
---|
493 | (node (ref IC4) (pin 5))
|
---|
494 | (node (ref C1) (pin 2))
|
---|
495 | (node (ref C2) (pin 2))
|
---|
496 | (node (ref P1) (pin 49))
|
---|
497 | (node (ref P2) (pin 4))
|
---|
498 | (node (ref P2) (pin 5))
|
---|
499 | (node (ref IC1) (pin 7)))
|
---|
500 | (net (code 31) (name "Net-(IC4-Pad10)")
|
---|
501 | (node (ref IC4) (pin 10))
|
---|
502 | (node (ref P2) (pin 3)))
|
---|
503 | (net (code 32) (name "Net-(IC4-Pad11)")
|
---|
504 | (node (ref IC4) (pin 11))
|
---|
505 | (node (ref P2) (pin 2)))
|
---|
506 | (net (code 33) (name "Net-(C5-Pad1)")
|
---|
507 | (node (ref R1) (pin 1))
|
---|
508 | (node (ref C5) (pin 1))
|
---|
509 | (node (ref P2) (pin 1)))
|
---|
510 | (net (code 34) (name //RD)
|
---|
511 | (node (ref IC4) (pin 4))
|
---|
512 | (node (ref P1) (pin 32)))
|
---|
513 | (net (code 35) (name //WR)
|
---|
514 | (node (ref IC4) (pin 3))
|
---|
515 | (node (ref P1) (pin 33)))
|
---|
516 | (net (code 36) (name VCC)
|
---|
517 | (node (ref C1) (pin 1))
|
---|
518 | (node (ref IC1) (pin 14))
|
---|
519 | (node (ref C2) (pin 1))
|
---|
520 | (node (ref P1) (pin 27))
|
---|
521 | (node (ref IC4) (pin 28))
|
---|
522 | (node (ref IC3) (pin 16))
|
---|
523 | (node (ref IC2) (pin 14))
|
---|
524 | (node (ref U1) (pin 3))
|
---|
525 | (node (ref R1) (pin 2))
|
---|
526 | (node (ref C3) (pin 1))
|
---|
527 | (node (ref C4) (pin 1)))
|
---|
528 | (net (code 37) (name "Net-(IC4-Pad24)")
|
---|
529 | (node (ref IC4) (pin 24)))
|
---|
530 | (net (code 38) (name "Net-(IC4-Pad6)")
|
---|
531 | (node (ref IC4) (pin 6)))
|
---|
532 | (net (code 39) (name /D7)
|
---|
533 | (node (ref IC4) (pin 22))
|
---|
534 | (node (ref P1) (pin 19)))
|
---|
535 | (net (code 40) (name /D6)
|
---|
536 | (node (ref IC4) (pin 21))
|
---|
537 | (node (ref P1) (pin 20)))
|
---|
538 | (net (code 41) (name /D5)
|
---|
539 | (node (ref P1) (pin 21))
|
---|
540 | (node (ref IC4) (pin 20)))
|
---|
541 | (net (code 42) (name /D4)
|
---|
542 | (node (ref P1) (pin 22))
|
---|
543 | (node (ref IC4) (pin 19)))
|
---|
544 | (net (code 43) (name /D3)
|
---|
545 | (node (ref IC4) (pin 18))
|
---|
546 | (node (ref P1) (pin 23)))
|
---|
547 | (net (code 44) (name /D2)
|
---|
548 | (node (ref P1) (pin 24))
|
---|
549 | (node (ref IC4) (pin 17)))
|
---|
550 | (net (code 45) (name /D1)
|
---|
551 | (node (ref P1) (pin 25))
|
---|
552 | (node (ref IC4) (pin 16)))
|
---|
553 | (net (code 46) (name /D0)
|
---|
554 | (node (ref IC4) (pin 15))
|
---|
555 | (node (ref P1) (pin 26)))
|
---|
556 | (net (code 47) (name "Net-(P1-Pad34)")
|
---|
557 | (node (ref P1) (pin 34)))
|
---|
558 | (net (code 48) (name "Net-(P1-Pad39)")
|
---|
559 | (node (ref P1) (pin 39)))
|
---|
560 | (net (code 49) (name "Net-(P1-Pad35)")
|
---|
561 | (node (ref P1) (pin 35)))
|
---|
562 | (net (code 50) (name "Net-(P1-Pad1)")
|
---|
563 | (node (ref P1) (pin 1)))
|
---|
564 | (net (code 51) (name "Net-(P1-Pad44)")
|
---|
565 | (node (ref P1) (pin 44)))
|
---|
566 | (net (code 52) (name "Net-(P1-Pad48)")
|
---|
567 | (node (ref P1) (pin 48)))
|
---|
568 | (net (code 53) (name /A12)
|
---|
569 | (node (ref P1) (pin 6))
|
---|
570 | (node (ref IC1) (pin 1)))
|
---|
571 | (net (code 54) (name /A8)
|
---|
572 | (node (ref IC2) (pin 6))
|
---|
573 | (node (ref P1) (pin 10)))
|
---|
574 | (net (code 55) (name /A4)
|
---|
575 | (node (ref P1) (pin 14))
|
---|
576 | (node (ref IC2) (pin 11)))
|
---|
577 | (net (code 56) (name "Net-(P1-Pad30)")
|
---|
578 | (node (ref P1) (pin 30)))
|
---|
579 | (net (code 57) (name "Net-(P1-Pad36)")
|
---|
580 | (node (ref P1) (pin 36)))
|
---|
581 | (net (code 58) (name "Net-(P1-Pad38)")
|
---|
582 | (node (ref P1) (pin 38)))
|
---|
583 | (net (code 59) (name "Net-(P1-Pad40)")
|
---|
584 | (node (ref P1) (pin 40)))
|
---|
585 | (net (code 60) (name "Net-(C6-Pad1)")
|
---|
586 | (node (ref C6) (pin 1))
|
---|
587 | (node (ref IC4) (pin 9)))
|
---|
588 | (net (code 61) (name +3V3)
|
---|
589 | (node (ref U1) (pin 2))
|
---|
590 | (node (ref C7) (pin 1))
|
---|
591 | (node (ref U2) (pin 4)))
|
---|
592 | (net (code 62) (name /SD_DO)
|
---|
593 | (node (ref IC4) (pin 7))
|
---|
594 | (node (ref U2) (pin 7)))
|
---|
595 | (net (code 63) (name /SD_CLK)
|
---|
596 | (node (ref U2) (pin 5))
|
---|
597 | (node (ref IC4) (pin 26)))
|
---|
598 | (net (code 64) (name /SD_DI)
|
---|
599 | (node (ref U2) (pin 2))
|
---|
600 | (node (ref IC4) (pin 25)))
|
---|
601 | (net (code 65) (name //SD_CS)
|
---|
602 | (node (ref U2) (pin 1))
|
---|
603 | (node (ref IC4) (pin 23)))
|
---|
604 | (net (code 66) (name /FEBx)
|
---|
605 | (node (ref IC3) (pin 14)))
|
---|
606 | (net (code 67) (name "Net-(U2-Pad8)")
|
---|
607 | (node (ref U2) (pin 8)))
|
---|
608 | (net (code 68) (name "Net-(U2-Pad15)")
|
---|
609 | (node (ref U2) (pin 15)))
|
---|
610 | (net (code 69) (name "Net-(U2-Pad14)")
|
---|
611 | (node (ref U2) (pin 14)))
|
---|
612 | (net (code 70) (name "Net-(IC3-Pad10)")
|
---|
613 | (node (ref IC3) (pin 10)))
|
---|
614 | (net (code 71) (name "Net-(IC3-Pad9)")
|
---|
615 | (node (ref IC3) (pin 9)))
|
---|
616 | (net (code 72) (name "Net-(IC3-Pad11)")
|
---|
617 | (node (ref IC3) (pin 11)))
|
---|
618 | (net (code 73) (name "Net-(IC3-Pad12)")
|
---|
619 | (node (ref IC3) (pin 12)))
|
---|
620 | (net (code 74) (name "Net-(IC3-Pad13)")
|
---|
621 | (node (ref IC3) (pin 13)))
|
---|
622 | (net (code 75) (name "Net-(IC3-Pad15)")
|
---|
623 | (node (ref IC3) (pin 15)))
|
---|
624 | (net (code 76) (name /CE1)
|
---|
625 | (node (ref IC2) (pin 1))
|
---|
626 | (node (ref IC3) (pin 6)))
|
---|
627 | (net (code 77) (name //IORQ)
|
---|
628 | (node (ref P1) (pin 31))
|
---|
629 | (node (ref IC3) (pin 5)))
|
---|
630 | (net (code 78) (name "Net-(IC2-Pad13)")
|
---|
631 | (node (ref IC3) (pin 3))
|
---|
632 | (node (ref IC2) (pin 13)))
|
---|
633 | (net (code 79) (name /A0)
|
---|
634 | (node (ref P1) (pin 18))
|
---|
635 | (node (ref IC4) (pin 8)))
|
---|
636 | (net (code 80) (name "Net-(IC4-Pad2)")
|
---|
637 | (node (ref IC4) (pin 2)))
|
---|
638 | (net (code 81) (name "Net-(IC4-Pad1)")
|
---|
639 | (node (ref IC4) (pin 1)))))
|
---|