Changeset 7d84448 in avrstuff for CPC stuff/gemini/ramcard.net


Ignore:
Timestamp:
Jan 21, 2022, 11:09:00 PM (2 years ago)
Author:
PulkoMandy <pulkomandy@…>
Branches:
main
Children:
c27bc0f
Parents:
fb852a1
Message:

Gemini: update after review by Zik (thanks!)

File:
1 edited

Legend:

Unmodified
Added
Removed
  • CPC stuff/gemini/ramcard.net

    rfb852a1 r7d84448  
    22  (design
    33    (source "C:\\Users\\pulkomandy\\Documents\\GitHub\\avrstuff\\CPC stuff\\gemini\\ramcard.sch")
    4     (date "10/10/2021 23:35:31")
     4    (date "21/01/2022 20:25:40")
    55    (tool "Eeschema (5.1.10)-1")
    66    (sheet (number 1) (name /) (tstamps /)
     
    1616        (comment (number 4) (value "")))))
    1717  (components
    18     (comp (ref U2)
    19       (value 74LS574)
    20       (footprint Package_SO:SOIC-20W_7.5x12.8mm_P1.27mm)
    21       (datasheet http://www.ti.com/lit/gpn/sn74LS574)
    22       (libsource (lib 74xx) (part 74LS574) (description "8-bit Register, 3-state outputs"))
    23       (sheetpath (names /) (tstamps /))
    24       (tstamp 5FB3A5F5))
    2518    (comp (ref C1)
    2619      (value C)
     
    131124      (libsource (lib Device) (part R) (description Resistor))
    132125      (sheetpath (names /) (tstamps /))
    133       (tstamp 61E51CEA)))
     126      (tstamp 61E51CEA))
     127    (comp (ref D3)
     128      (value DIODE)
     129      (footprint Diodes_SMD:D_1206)
     130      (datasheet ~)
     131      (libsource (lib pspice) (part DIODE) (description "Diode symbol for simulation only. Pin order incompatible with official kicad footprints"))
     132      (sheetpath (names /) (tstamps /))
     133      (tstamp 6165927E))
     134    (comp (ref U2)
     135      (value 74AHCT273)
     136      (footprint Housings_SOIC:SOIC-20W_7.5x12.8mm_Pitch1.27mm)
     137      (datasheet https://assets.nexperia.com/documents/data-sheet/74AHC_AHCT273.pdf)
     138      (libsource (lib 74xx) (part 74AHCT273) (description "8-bit D Flip-Flop, reset"))
     139      (sheetpath (names /) (tstamps /))
     140      (tstamp 61EB5442)))
    134141  (libparts
    135     (libpart (lib 74xx) (part 74LS574)
     142    (libpart (lib 74xx) (part 74LS273)
    136143      (aliases
    137         (alias 74HCT574))
    138       (description "8-bit Register, 3-state outputs")
    139       (docs http://www.ti.com/lit/gpn/sn74LS574)
    140       (footprints
    141         (fp DIP?20*))
     144        (alias 74HC273)
     145        (alias 74HCT273)
     146        (alias 74AHC273)
     147        (alias 74AHCT273))
     148      (description "8-bit D Flip-Flop, reset")
     149      (docs http://www.ti.com/lit/gpn/sn74LS273)
     150      (footprints
     151        (fp DIP?20*)
     152        (fp SO?20*)
     153        (fp SOIC?20*))
    142154      (fields
    143155        (field (name Reference) U)
    144         (field (name Value) 74LS574))
    145       (pins
    146         (pin (num 1) (name OE) (type input))
    147         (pin (num 2) (name D0) (type input))
    148         (pin (num 3) (name D1) (type input))
    149         (pin (num 4) (name D2) (type input))
    150         (pin (num 5) (name D3) (type input))
    151         (pin (num 6) (name D4) (type input))
    152         (pin (num 7) (name D5) (type input))
    153         (pin (num 8) (name D6) (type input))
    154         (pin (num 9) (name D7) (type input))
     156        (field (name Value) 74LS273))
     157      (pins
     158        (pin (num 1) (name ~Mr) (type input))
     159        (pin (num 2) (name Q0) (type output))
     160        (pin (num 3) (name D0) (type input))
     161        (pin (num 4) (name D1) (type input))
     162        (pin (num 5) (name Q1) (type output))
     163        (pin (num 6) (name Q2) (type output))
     164        (pin (num 7) (name D2) (type input))
     165        (pin (num 8) (name D3) (type input))
     166        (pin (num 9) (name Q3) (type output))
    155167        (pin (num 10) (name GND) (type power_in))
    156168        (pin (num 11) (name Cp) (type input))
    157         (pin (num 12) (name Q7) (type 3state))
    158         (pin (num 13) (name Q6) (type 3state))
    159         (pin (num 14) (name Q5) (type 3state))
    160         (pin (num 15) (name Q4) (type 3state))
    161         (pin (num 16) (name Q3) (type 3state))
    162         (pin (num 17) (name Q2) (type 3state))
    163         (pin (num 18) (name Q1) (type 3state))
    164         (pin (num 19) (name Q0) (type 3state))
     169        (pin (num 12) (name Q4) (type output))
     170        (pin (num 13) (name D4) (type input))
     171        (pin (num 14) (name D5) (type input))
     172        (pin (num 15) (name Q5) (type output))
     173        (pin (num 16) (name Q6) (type output))
     174        (pin (num 17) (name D6) (type input))
     175        (pin (num 18) (name D7) (type input))
     176        (pin (num 19) (name Q7) (type output))
    165177        (pin (num 20) (name VCC) (type power_in))))
    166178    (libpart (lib 74xx) (part 74LS688)
     
    396408        (pin (num 4) (name A) (type passive))
    397409        (pin (num 5) (name B) (type passive))
    398         (pin (num 6) (name C) (type passive)))))
     410        (pin (num 6) (name C) (type passive))))
     411    (libpart (lib pspice) (part DIODE)
     412      (description "Diode symbol for simulation only. Pin order incompatible with official kicad footprints")
     413      (docs ~)
     414      (fields
     415        (field (name Reference) D)
     416        (field (name Value) DIODE))
     417      (pins
     418        (pin (num 1) (name K) (type input))
     419        (pin (num 2) (name A) (type input)))))
    399420  (libraries
    400421    (library (logical 74xx)
    401422      (uri "C:\\Program Files\\KiCad\\share\\kicad\\library/74xx.lib"))
    402423    (library (logical ATF22v10)
    403       (uri "C:\\Users\\pulkomandy\\Documents\\GitHub\\avrstuff\\CPC stuff\\kicadlibs\\2021-10-10_11-41-49\\2021-10-10_11-41-49.lib"))
     424      (uri "C:/Users/pulkomandy/Documents/GitHub/avrstuff/CPC stuff/kicadlibs/2021-10-10_11-41-49/2021-10-10_11-41-49.lib"))
    404425    (library (logical Connector_Generic)
    405426      (uri "C:\\Program Files\\KiCad\\share\\kicad\\library/Connector_Generic.lib"))
     
    409430      (uri "C:\\Users\\pulkomandy\\Documents\\GitHub\\avrstuff\\CPC stuff\\gemini/LY6220488.lib"))
    410431    (library (logical Switch)
    411       (uri "C:\\Program Files\\KiCad\\share\\kicad\\library/Switch.lib")))
     432      (uri "C:\\Program Files\\KiCad\\share\\kicad\\library/Switch.lib"))
     433    (library (logical pspice)
     434      (uri "C:\\Program Files\\KiCad\\share\\kicad\\library/pspice.lib")))
    412435  (nets
    413     (net (code 1) (name "Net-(J1-Pad30)")
    414       (node (ref J1) (pin 30)))
    415     (net (code 2) (name "Net-(J1-Pad34)")
    416       (node (ref J1) (pin 34)))
    417     (net (code 3) (name "Net-(J1-Pad36)")
    418       (node (ref J1) (pin 36)))
    419     (net (code 4) (name "Net-(J1-Pad38)")
     436    (net (code 1) (name "Net-(J1-Pad40)")
     437      (node (ref J1) (pin 40)))
     438    (net (code 2) (name "Net-(J1-Pad42)")
     439      (node (ref J1) (pin 42)))
     440    (net (code 3) (name "Net-(D3-Pad2)")
     441      (node (ref D3) (pin 2))
     442      (node (ref J1) (pin 45)))
     443    (net (code 4) (name /NCO)
     444      (node (ref U5) (pin 19))
     445      (node (ref U3) (pin 3)))
     446    (net (code 5) (name /A8)
     447      (node (ref U3) (pin 4))
     448      (node (ref J1) (pin 10))
     449      (node (ref SW1) (pin 6))
     450      (node (ref U4) (pin 39)))
     451    (net (code 6) (name /A9)
     452      (node (ref J1) (pin 9))
     453      (node (ref U3) (pin 5))
     454      (node (ref U4) (pin 28))
     455      (node (ref SW1) (pin 3)))
     456    (net (code 7) (name "Net-(U3-Pad6)")
     457      (node (ref U3) (pin 6)))
     458    (net (code 8) (name "Net-(J1-Pad38)")
    420459      (node (ref J1) (pin 38)))
    421     (net (code 5) (name /A14)
    422       (node (ref J1) (pin 4))
    423       (node (ref U1) (pin 10)))
    424     (net (code 6) (name /MA7)
    425       (node (ref SW1) (pin 2))
    426       (node (ref U2) (pin 8)))
    427     (net (code 7) (name /MA8)
    428       (node (ref U2) (pin 9))
    429       (node (ref SW1) (pin 5)))
    430     (net (code 8) (name /A12)
    431       (node (ref J1) (pin 6))
    432       (node (ref U4) (pin 25)))
    433     (net (code 9) (name /RAMDIS)
    434       (node (ref J1) (pin 45))
     460    (net (code 9) (name /~CRTC)
     461      (node (ref U3) (pin 2))
     462      (node (ref U1) (pin 15)))
     463    (net (code 10) (name /RMR2)
     464      (node (ref U1) (pin 16)))
     465    (net (code 11) (name /ASIC)
     466      (node (ref D2) (pin 1))
     467      (node (ref U1) (pin 17)))
     468    (net (code 12) (name /RAMDIS)
     469      (node (ref U4) (pin 40))
    435470      (node (ref U1) (pin 19))
    436       (node (ref U4) (pin 40)))
    437     (net (code 10) (name "Net-(J1-Pad42)")
    438       (node (ref J1) (pin 42)))
    439     (net (code 11) (name "Net-(J1-Pad40)")
    440       (node (ref J1) (pin 40)))
    441     (net (code 12) (name GND)
    442       (node (ref R2) (pin 1))
    443       (node (ref C4) (pin 2))
    444       (node (ref U5) (pin 1))
    445       (node (ref C6) (pin 2))
    446       (node (ref U5) (pin 10))
    447       (node (ref U4) (pin 34))
    448       (node (ref U2) (pin 10))
    449       (node (ref U2) (pin 1))
    450       (node (ref U3) (pin 13))
    451       (node (ref U3) (pin 12))
    452       (node (ref U4) (pin 12))
    453       (node (ref R1) (pin 1))
    454       (node (ref C5) (pin 2))
    455       (node (ref C3) (pin 2))
    456       (node (ref J1) (pin 2))
    457       (node (ref SW1) (pin 1))
    458       (node (ref SW1) (pin 4))
    459       (node (ref U1) (pin 12))
    460       (node (ref C2) (pin 2))
    461       (node (ref C1) (pin 2))
    462       (node (ref J1) (pin 49)))
    463     (net (code 13) (name /CRTC)
    464       (node (ref U1) (pin 15))
    465       (node (ref U3) (pin 2)))
    466     (net (code 14) (name /RMR2)
    467       (node (ref U1) (pin 16)))
    468     (net (code 15) (name /RAMWR)
     471      (node (ref D3) (pin 1)))
     472    (net (code 13) (name /XA15)
     473      (node (ref U4) (pin 22))
     474      (node (ref U1) (pin 20)))
     475    (net (code 14) (name /XA14)
     476      (node (ref U4) (pin 23))
     477      (node (ref U1) (pin 21)))
     478    (net (code 15) (name /~RAMWR)
    469479      (node (ref U1) (pin 22))
    470480      (node (ref U4) (pin 17)))
    471     (net (code 16) (name /XA14)
    472       (node (ref U4) (pin 23))
    473       (node (ref U1) (pin 21)))
    474     (net (code 17) (name /XA15)
    475       (node (ref U4) (pin 22))
    476       (node (ref U1) (pin 20)))
    477     (net (code 18) (name /UNLOCK)
    478       (node (ref D1) (pin 1))
    479       (node (ref U3) (pin 22))
    480       (node (ref U1) (pin 18)))
    481     (net (code 19) (name /ASIC)
    482       (node (ref D2) (pin 1))
    483       (node (ref U1) (pin 17)))
    484     (net (code 20) (name VCC)
    485       (node (ref C1) (pin 1))
    486       (node (ref U2) (pin 20))
    487       (node (ref C2) (pin 1))
    488       (node (ref J1) (pin 27))
    489       (node (ref U3) (pin 24))
    490       (node (ref C5) (pin 1))
    491       (node (ref U5) (pin 20))
    492       (node (ref C3) (pin 1))
    493       (node (ref U4) (pin 33))
    494       (node (ref U1) (pin 24))
    495       (node (ref C6) (pin 1))
    496       (node (ref U4) (pin 11))
    497       (node (ref C4) (pin 1)))
    498     (net (code 21) (name /D0)
    499       (node (ref U5) (pin 12))
    500       (node (ref J1) (pin 26))
    501       (node (ref U2) (pin 2))
    502       (node (ref U4) (pin 9)))
    503     (net (code 22) (name /D1)
     481    (net (code 16) (name "Net-(J1-Pad30)")
     482      (node (ref J1) (pin 30)))
     483    (net (code 17) (name "Net-(J1-Pad34)")
     484      (node (ref J1) (pin 34)))
     485    (net (code 18) (name "Net-(J1-Pad36)")
     486      (node (ref J1) (pin 36)))
     487    (net (code 19) (name "Net-(D1-Pad2)")
     488      (node (ref R1) (pin 2))
     489      (node (ref D1) (pin 2)))
     490    (net (code 20) (name /PRBS7)
     491      (node (ref U5) (pin 2))
     492      (node (ref U3) (pin 23)))
     493    (net (code 21) (name "Net-(D2-Pad2)")
     494      (node (ref D2) (pin 2))
     495      (node (ref R2) (pin 2)))
     496    (net (code 22) (name /CLKIN)
     497      (node (ref U3) (pin 1))
     498      (node (ref U3) (pin 14)))
     499    (net (code 23) (name /D7)
     500      (node (ref U5) (pin 3))
     501      (node (ref J1) (pin 19))
     502      (node (ref U4) (pin 36))
     503      (node (ref U1) (pin 2)))
     504    (net (code 24) (name /D6)
     505      (node (ref U5) (pin 5))
     506      (node (ref U4) (pin 35))
     507      (node (ref U1) (pin 3))
     508      (node (ref J1) (pin 20)))
     509    (net (code 25) (name /D5)
     510      (node (ref U4) (pin 32))
     511      (node (ref J1) (pin 21))
     512      (node (ref U1) (pin 4))
     513      (node (ref U5) (pin 7))
     514      (node (ref U2) (pin 14)))
     515    (net (code 26) (name /D4)
     516      (node (ref U5) (pin 9))
     517      (node (ref U2) (pin 13))
     518      (node (ref J1) (pin 22))
     519      (node (ref U4) (pin 31))
     520      (node (ref U1) (pin 5)))
     521    (net (code 27) (name /XA18)
     522      (node (ref U4) (pin 19))
     523      (node (ref U2) (pin 15)))
     524    (net (code 28) (name /XA19)
     525      (node (ref U4) (pin 18))
     526      (node (ref U2) (pin 16)))
     527    (net (code 29) (name /MA7)
     528      (node (ref U2) (pin 17))
     529      (node (ref SW1) (pin 2)))
     530    (net (code 30) (name /MA8)
     531      (node (ref U2) (pin 18))
     532      (node (ref SW1) (pin 5)))
     533    (net (code 31) (name /XA20)
     534      (node (ref U4) (pin 16))
     535      (node (ref U2) (pin 19)))
     536    (net (code 32) (name /XD0)
     537      (node (ref U1) (pin 9))
     538      (node (ref U2) (pin 2)))
     539    (net (code 33) (name /XD1)
     540      (node (ref U1) (pin 8))
     541      (node (ref U2) (pin 5)))
     542    (net (code 34) (name /XA16)
     543      (node (ref U2) (pin 9))
     544      (node (ref U4) (pin 21)))
     545    (net (code 35) (name /~RESET)
     546      (node (ref U2) (pin 1))
     547      (node (ref U1) (pin 13))
     548      (node (ref J1) (pin 41))
     549      (node (ref U3) (pin 7)))
     550    (net (code 36) (name /XA17)
     551      (node (ref U4) (pin 20))
     552      (node (ref U2) (pin 12)))
     553    (net (code 37) (name /~MMR)
     554      (node (ref U2) (pin 11))
     555      (node (ref U1) (pin 23)))
     556    (net (code 38) (name /~MREQ)
     557      (node (ref J1) (pin 28))
     558      (node (ref U4) (pin 6)))
     559    (net (code 39) (name /~WR)
     560      (node (ref J1) (pin 33))
     561      (node (ref U1) (pin 14)))
     562    (net (code 40) (name /~IORQ)
     563      (node (ref J1) (pin 31))
     564      (node (ref U1) (pin 1)))
     565    (net (code 41) (name /D3)
     566      (node (ref U1) (pin 6))
     567      (node (ref U2) (pin 8))
     568      (node (ref U5) (pin 18))
     569      (node (ref J1) (pin 23))
     570      (node (ref U4) (pin 14)))
     571    (net (code 42) (name /D2)
     572      (node (ref U5) (pin 16))
     573      (node (ref U4) (pin 13))
     574      (node (ref U2) (pin 7))
     575      (node (ref J1) (pin 24)))
     576    (net (code 43) (name /D1)
     577      (node (ref U5) (pin 14))
    504578      (node (ref U4) (pin 10))
    505579      (node (ref J1) (pin 25))
     580      (node (ref U2) (pin 4)))
     581    (net (code 44) (name /D0)
     582      (node (ref U4) (pin 9))
     583      (node (ref U5) (pin 12))
    506584      (node (ref U2) (pin 3))
    507       (node (ref U5) (pin 14)))
    508     (net (code 23) (name /D2)
    509       (node (ref U2) (pin 4))
    510       (node (ref J1) (pin 24))
    511       (node (ref U5) (pin 16))
    512       (node (ref U4) (pin 13)))
    513     (net (code 24) (name /D3)
    514       (node (ref U2) (pin 5))
    515       (node (ref U4) (pin 14))
    516       (node (ref U5) (pin 18))
    517       (node (ref U1) (pin 6))
    518       (node (ref J1) (pin 23)))
    519     (net (code 25) (name /NCO)
    520       (node (ref U3) (pin 3))
    521       (node (ref U5) (pin 19)))
    522     (net (code 26) (name /PRBS6)
     585      (node (ref J1) (pin 26)))
     586    (net (code 45) (name "Net-(U3-Pad8)")
     587      (node (ref U3) (pin 8)))
     588    (net (code 46) (name "Net-(U3-Pad9)")
     589      (node (ref U3) (pin 9)))
     590    (net (code 47) (name "Net-(U3-Pad10)")
     591      (node (ref U3) (pin 10)))
     592    (net (code 48) (name "Net-(U3-Pad11)")
     593      (node (ref U3) (pin 11)))
     594    (net (code 49) (name /UNLOCK)
     595      (node (ref U3) (pin 22))
     596      (node (ref U1) (pin 18))
     597      (node (ref D1) (pin 1)))
     598    (net (code 50) (name VCC)
     599      (node (ref U4) (pin 33))
     600      (node (ref C4) (pin 1))
     601      (node (ref J1) (pin 27))
     602      (node (ref U2) (pin 20))
     603      (node (ref U1) (pin 24))
     604      (node (ref U5) (pin 20))
     605      (node (ref C6) (pin 1))
     606      (node (ref U3) (pin 24))
     607      (node (ref U4) (pin 11))
     608      (node (ref C5) (pin 1))
     609      (node (ref C3) (pin 1))
     610      (node (ref C2) (pin 1))
     611      (node (ref C1) (pin 1)))
     612    (net (code 51) (name /PRBS0)
     613      (node (ref U3) (pin 15))
     614      (node (ref U5) (pin 11)))
     615    (net (code 52) (name /PRBS1)
     616      (node (ref U3) (pin 16))
     617      (node (ref U5) (pin 13)))
     618    (net (code 53) (name /PRBS2)
     619      (node (ref U5) (pin 15))
     620      (node (ref U3) (pin 17)))
     621    (net (code 54) (name /PRBS3)
     622      (node (ref U5) (pin 17))
     623      (node (ref U3) (pin 18)))
     624    (net (code 55) (name /PRBS4)
     625      (node (ref U3) (pin 19))
     626      (node (ref U5) (pin 8)))
     627    (net (code 56) (name /PRBS5)
     628      (node (ref U3) (pin 20))
     629      (node (ref U5) (pin 6)))
     630    (net (code 57) (name /PRBS6)
    523631      (node (ref U3) (pin 21))
    524632      (node (ref U5) (pin 4)))
    525     (net (code 27) (name /PRBS7)
    526       (node (ref U3) (pin 23))
    527       (node (ref U5) (pin 2)))
    528     (net (code 28) (name "Net-(D1-Pad2)")
    529       (node (ref D1) (pin 2))
    530       (node (ref R1) (pin 2)))
    531     (net (code 29) (name "Net-(D2-Pad2)")
    532       (node (ref D2) (pin 2))
    533       (node (ref R2) (pin 2)))
    534     (net (code 30) (name /A9)
    535       (node (ref U4) (pin 28))
    536       (node (ref U3) (pin 5))
    537       (node (ref J1) (pin 9)))
    538     (net (code 31) (name /A8)
    539       (node (ref U3) (pin 4))
    540       (node (ref SW1) (pin 6))
    541       (node (ref U4) (pin 39))
    542       (node (ref J1) (pin 10)))
    543     (net (code 32) (name /CLKIN)
    544       (node (ref U3) (pin 1))
    545       (node (ref U3) (pin 14)))
    546     (net (code 33) (name /D4)
    547       (node (ref U5) (pin 9))
    548       (node (ref U4) (pin 31))
    549       (node (ref U2) (pin 6))
    550       (node (ref U1) (pin 5))
    551       (node (ref J1) (pin 22)))
    552     (net (code 34) (name /PRBS4)
    553       (node (ref U3) (pin 19))
    554       (node (ref U5) (pin 8)))
    555     (net (code 35) (name /D5)
    556       (node (ref U2) (pin 7))
    557       (node (ref U4) (pin 32))
    558       (node (ref U5) (pin 7))
    559       (node (ref U1) (pin 4))
    560       (node (ref J1) (pin 21)))
    561     (net (code 36) (name /PRBS5)
    562       (node (ref U5) (pin 6))
    563       (node (ref U3) (pin 20)))
    564     (net (code 37) (name /D6)
    565       (node (ref U4) (pin 35))
    566       (node (ref J1) (pin 20))
    567       (node (ref U1) (pin 3))
    568       (node (ref U5) (pin 5)))
    569     (net (code 38) (name /RESET)
    570       (node (ref U1) (pin 13))
    571       (node (ref U3) (pin 7))
    572       (node (ref J1) (pin 41)))
    573     (net (code 39) (name "Net-(U3-Pad6)")
    574       (node (ref U3) (pin 6)))
    575     (net (code 40) (name "Net-(U3-Pad8)")
    576       (node (ref U3) (pin 8)))
    577     (net (code 41) (name "Net-(U3-Pad9)")
    578       (node (ref U3) (pin 9)))
    579     (net (code 42) (name /D7)
    580       (node (ref U1) (pin 2))
    581       (node (ref U5) (pin 3))
    582       (node (ref J1) (pin 19))
    583       (node (ref U4) (pin 36)))
    584     (net (code 43) (name /PRBS3)
    585       (node (ref U3) (pin 18))
    586       (node (ref U5) (pin 17)))
    587     (net (code 44) (name /PRBS2)
    588       (node (ref U5) (pin 15))
    589       (node (ref U3) (pin 17)))
    590     (net (code 45) (name /PRBS1)
    591       (node (ref U5) (pin 13))
    592       (node (ref U3) (pin 16)))
    593     (net (code 46) (name /PRBS0)
    594       (node (ref U5) (pin 11))
    595       (node (ref U3) (pin 15)))
    596     (net (code 47) (name "Net-(U3-Pad11)")
    597       (node (ref U3) (pin 11)))
    598     (net (code 48) (name "Net-(U3-Pad10)")
    599       (node (ref U3) (pin 10)))
    600     (net (code 49) (name IORQ)
    601       (node (ref J1) (pin 31))
    602       (node (ref U1) (pin 1)))
    603     (net (code 50) (name "Net-(J1-Pad1)")
    604       (node (ref J1) (pin 1)))
    605     (net (code 51) (name "Net-(J1-Pad29)")
     633    (net (code 58) (name "Net-(J1-Pad35)")
     634      (node (ref J1) (pin 35)))
     635    (net (code 59) (name "Net-(J1-Pad37)")
     636      (node (ref J1) (pin 37)))
     637    (net (code 60) (name "Net-(J1-Pad39)")
     638      (node (ref J1) (pin 39)))
     639    (net (code 61) (name "Net-(J1-Pad43)")
     640      (node (ref J1) (pin 43)))
     641    (net (code 62) (name "Net-(J1-Pad47)")
     642      (node (ref J1) (pin 47)))
     643    (net (code 63) (name "Net-(J1-Pad32)")
     644      (node (ref J1) (pin 32)))
     645    (net (code 64) (name "Net-(J1-Pad29)")
    606646      (node (ref J1) (pin 29)))
    607     (net (code 52) (name "Net-(J1-Pad35)")
    608       (node (ref J1) (pin 35)))
    609     (net (code 53) (name "Net-(J1-Pad37)")
    610       (node (ref J1) (pin 37)))
    611     (net (code 54) (name "Net-(J1-Pad39)")
    612       (node (ref J1) (pin 39)))
    613     (net (code 55) (name "Net-(J1-Pad43)")
    614       (node (ref J1) (pin 43)))
    615     (net (code 56) (name "Net-(J1-Pad47)")
    616       (node (ref J1) (pin 47)))
    617     (net (code 57) (name WR)
    618       (node (ref J1) (pin 33))
    619       (node (ref U1) (pin 14)))
    620     (net (code 58) (name "Net-(J1-Pad50)")
    621       (node (ref J1) (pin 50)))
    622     (net (code 59) (name "Net-(J1-Pad32)")
    623       (node (ref J1) (pin 32)))
    624     (net (code 60) (name RAMRD)
    625       (node (ref U4) (pin 41))
    626       (node (ref J1) (pin 44)))
    627     (net (code 61) (name /MMR)
    628       (node (ref U1) (pin 23))
    629       (node (ref U2) (pin 11)))
    630     (net (code 62) (name /A5)
    631       (node (ref U4) (pin 44))
    632       (node (ref J1) (pin 13)))
    633     (net (code 63) (name /A4)
    634       (node (ref J1) (pin 14))
    635       (node (ref U4) (pin 1)))
    636     (net (code 64) (name /A3)
    637       (node (ref U4) (pin 2))
    638       (node (ref J1) (pin 15)))
    639     (net (code 65) (name /A2)
     647    (net (code 65) (name /A3)
     648      (node (ref J1) (pin 15))
     649      (node (ref U4) (pin 2)))
     650    (net (code 66) (name /A2)
    640651      (node (ref J1) (pin 16))
    641652      (node (ref U4) (pin 3)))
    642     (net (code 66) (name /A1)
    643       (node (ref J1) (pin 17))
    644       (node (ref U4) (pin 4)))
    645     (net (code 67) (name /A0)
     653    (net (code 67) (name /A1)
     654      (node (ref U4) (pin 4))
     655      (node (ref J1) (pin 17)))
     656    (net (code 68) (name /A0)
    646657      (node (ref J1) (pin 18))
    647658      (node (ref U4) (pin 5)))
    648     (net (code 68) (name /XA16)
    649       (node (ref U2) (pin 12))
    650       (node (ref U4) (pin 21)))
    651659    (net (code 69) (name "Net-(J1-Pad46)")
    652660      (node (ref J1) (pin 46)))
    653661    (net (code 70) (name "Net-(J1-Pad48)")
    654662      (node (ref J1) (pin 48)))
    655     (net (code 71) (name /XD0)
    656       (node (ref U2) (pin 19))
    657       (node (ref U1) (pin 9)))
    658     (net (code 72) (name /XD1)
    659       (node (ref U1) (pin 8))
    660       (node (ref U2) (pin 18)))
    661     (net (code 73) (name /XD2)
    662       (node (ref U1) (pin 7))
    663       (node (ref U2) (pin 17)))
    664     (net (code 74) (name /XA18)
    665       (node (ref U4) (pin 19))
    666       (node (ref U2) (pin 14)))
    667     (net (code 75) (name /XA17)
    668       (node (ref U2) (pin 13))
    669       (node (ref U4) (pin 20)))
    670     (net (code 76) (name MREQ)
    671       (node (ref U4) (pin 6))
    672       (node (ref J1) (pin 28)))
    673     (net (code 77) (name /A15)
     663    (net (code 71) (name "Net-(J1-Pad50)")
     664      (node (ref J1) (pin 50)))
     665    (net (code 72) (name "Net-(J1-Pad1)")
     666      (node (ref J1) (pin 1)))
     667    (net (code 73) (name /A4)
     668      (node (ref U4) (pin 1))
     669      (node (ref J1) (pin 14)))
     670    (net (code 74) (name /~RAMRD)
     671      (node (ref U4) (pin 41))
     672      (node (ref J1) (pin 44)))
     673    (net (code 75) (name /A7)
     674      (node (ref J1) (pin 11))
     675      (node (ref U4) (pin 42)))
     676    (net (code 76) (name /A6)
     677      (node (ref J1) (pin 12))
     678      (node (ref U4) (pin 43)))
     679    (net (code 77) (name /A5)
     680      (node (ref J1) (pin 13))
     681      (node (ref U4) (pin 44)))
     682    (net (code 78) (name /XD2)
     683      (node (ref U2) (pin 6))
     684      (node (ref U1) (pin 7)))
     685    (net (code 79) (name /A14)
     686      (node (ref U1) (pin 10))
     687      (node (ref J1) (pin 4)))
     688    (net (code 80) (name /A15)
    674689      (node (ref U1) (pin 11))
    675690      (node (ref J1) (pin 3)))
    676     (net (code 78) (name /A13)
    677       (node (ref U4) (pin 24))
    678       (node (ref J1) (pin 5)))
    679     (net (code 79) (name /A11)
     691    (net (code 81) (name GND)
     692      (node (ref U4) (pin 12))
     693      (node (ref U5) (pin 10))
     694      (node (ref U5) (pin 1))
     695      (node (ref J1) (pin 49))
     696      (node (ref C5) (pin 2))
     697      (node (ref C3) (pin 2))
     698      (node (ref SW1) (pin 1))
     699      (node (ref C2) (pin 2))
     700      (node (ref SW1) (pin 4))
     701      (node (ref C1) (pin 2))
     702      (node (ref C4) (pin 2))
     703      (node (ref C6) (pin 2))
     704      (node (ref U2) (pin 10))
     705      (node (ref J1) (pin 2))
     706      (node (ref R1) (pin 1))
     707      (node (ref R2) (pin 1))
     708      (node (ref U1) (pin 12))
     709      (node (ref U3) (pin 13))
     710      (node (ref U3) (pin 12))
     711      (node (ref U4) (pin 34)))
     712    (net (code 82) (name /A10)
     713      (node (ref U4) (pin 27))
     714      (node (ref J1) (pin 8)))
     715    (net (code 83) (name /A13)
     716      (node (ref J1) (pin 5))
     717      (node (ref U4) (pin 24)))
     718    (net (code 84) (name /A12)
     719      (node (ref J1) (pin 6))
     720      (node (ref U4) (pin 25)))
     721    (net (code 85) (name /A11)
    680722      (node (ref J1) (pin 7))
    681       (node (ref U4) (pin 26)))
    682     (net (code 80) (name /A10)
    683       (node (ref J1) (pin 8))
    684       (node (ref U4) (pin 27)))
    685     (net (code 81) (name /XA19)
    686       (node (ref U4) (pin 18))
    687       (node (ref U2) (pin 15)))
    688     (net (code 82) (name /XA20)
    689       (node (ref U4) (pin 16))
    690       (node (ref U2) (pin 16)))
    691     (net (code 83) (name /A6)
    692       (node (ref U4) (pin 43))
    693       (node (ref J1) (pin 12)))
    694     (net (code 84) (name /A7)
    695       (node (ref U4) (pin 42))
    696       (node (ref J1) (pin 11))
    697       (node (ref SW1) (pin 3)))))
     723      (node (ref U4) (pin 26)))))
Note: See TracChangeset for help on using the changeset viewer.